First-Principles Study of Schottky Barrier Heights on Metal/4H-SiC Polar ...
New Insights into the Interface Trap Generation during Hot Carrier Degrad...
Across-dimensional optical constellation de-aggregations from QAMs to PAM...
Towards Fully Decoupled End-to-End Person Search   (Open Access)
Comprehensive Study of NBTI and Off-State Reliabilty in Sub-20 nm DRAM Te...
An Ultrasensitive Ti3C2Tx MXene-based Soft Contact Lens for Continuous an...
Analysis of the Thickness of Multilayered Porous Silicon in the Cold Emis...
Design of off-axis aspheric four-mirror non-axial mechanical zoom optical...
High-performance SiO2-SiNx distributed Bragg reflectors fabricated by ion...
Design and analysis of a compact and broadband polarization beam splitter...
官方微信
友情链接

Smartphone-based portable electrochemical-colorimetric dual-mode biosensor for glucose detection in a co-reaction system

2024-03-08


Xu, Jiaqi; Shen, Jianing; Zhang, Bo; Zhang, Yao; Lv, Xiaoqing; Zhu, Guixian Source: Electrochimica Acta, v 481, March 20, 2024;

Abstract:

Regular monitoring of blood sugar levels is essential for diabetics, both for adjusting medication or insulin doses and for preventing complications like blindness, nerve damage, heart disease, and kidney failure. This paper presents a novel smartphone-based electrochemical-colorimetric dual-mode detecting system for detecting glucose at low concentrations. This system utilizes a smartphone as a mobile terminal to control the electrochemical circuit board and enable data analysis. The circuit board integrates cyclic voltammetry and differential pulse voltammetry, providing a low-cost and palm-sized solution for glucose detection. Additionally, digital image colorimetry is employed to enable efficient and accurate colorimetric detection. The use of glucose oxidase and horseradish peroxidase (GOx/HRP) in combination with 2,2′-azino-bis (3-ethylbenzothiazoline-6-sulfonic acid) ABTS substrates facilitates glucose dual-mode quantitative analysis in a-coreaction system. The electrochemical and colorimetric methods exhibit limits of detection of 0.467 µM and 10 µM, respectively. This system shows a point-of-care testing (POCT) potential for reliable and convenient monitoring of blood glucose levels, particularly for individuals with diabetes.

© 2024 (42 refs.)




关于我们
下载视频观看
联系方式
通信地址

北京市海淀区清华东路甲35号(林大北路中段) 北京912信箱 (100083)

电话

010-82304210/010-82305052(传真)

E-mail

semi@semi.ac.cn

交通地图
版权所有 中国科学院半导体研究所

备案号:京ICP备05085259-1号 京公网安备110402500052 中国科学院半导体所声明