In-Sensor Polarimetric Optoelectronic Computing Based on Gate-Tunable 2D ...
Multi-Color Detection of Single Sensor Based on Tellurium Relaxation Char...
Uncooled InAsSb- based high- speed mid- wave infrared barrier detector
High Frequency Mid-Infrared Quantum Cascade Laser Integrated With Grounde...
Multi-function sensing applications based on high Q-factor multi-Fano res...
High-power electrically pumped terahertz topological laser based on a sur...
Van der Waals polarity-engineered 3D integration of 2D complementary logic
Distinguishing the Charge Trapping Centers in CaF2-Based 2D Material MOSFETs
Influence of Growth Process on Suppression of Surface Morphological Defec...
High-Power External Spatial Beam Combining of 7-Channel Quantum Cascade L...
官方微信
友情链接

Dual quasi-bound states in the continuum of photonic crystal slab for simultaneous measurement of refractive index and temperature with low demodulation deviation

2024-07-11


Author(s): Han, Z (Han, Zhe); Sheng, DH (Sheng, Donghe); Yu, LD (Yu, Ludan); Zhai, JR (Zhai, Jieru); Dong, TP (Dong, Tianpei); Liu, YY (Liu, Yuanyuan); Tian, HP (Tian, Huiping)

Source: OPTICS AND LASER TECHNOLOGY Volume: 177  Article Number: 111171  

DOI: 10.1016/j.optlastec.2024.111171  Published Date: 2024 OCT  

Abstract: In this paper, a silicon photonic crystal slab driven by dual symmetry breaking-induced quasi-bound states in the continuum (quasi-BICs) is theoretically proposed for high-performance refractive index and temperature sensing. The suspended photonic crystal slab structure and the small inclination angle alpha of trapezoidal nanoholes enhance the sensitivities and Q-factors of quasi-BICs, respectively. The effects of geometric parameters and polarization angle of light source on quasi-BICs are analyzed. Numerical results show the Q-factors of dual quasi-BICs (QBIC1 and QBIC2), which are dominated by electric quadrupole (EQ) and magnetic dipole (MD), are close to 106 and 105, respectively. The refractive index sensitivities of QBIC1 and QBIC2 exceed 700 nm/refractive index unit (RIU). In addition, the demodulation deviation caused by the resolution of the sensor is calculated by analyzing the two-dimensional sensing matrix. The simultaneous enhancement of Q-factor and sensitivity creates favorable conditions for reducing the demodulation deviation. The maximum demodulation deviations of refractive index and temperature of the designed sensor are 3.1 x 10-6 RIU and 0.1 K, respectively. Our work shows the potential of quasi-BICs for developing high-performance dual-parameter and multi-parameter detection.




关于我们
下载视频观看
联系方式
通信地址

北京市海淀区清华东路甲35号(林大北路中段) 北京912信箱 (100083)

电话

010-82304210/010-82305052(传真)

E-mail

semi@semi.ac.cn

交通地图
版权所有 中国科学院半导体研究所

备案号:京ICP备05085259-1号 京公网安备110402500052 中国科学院半导体所声明