In-Sensor Polarimetric Optoelectronic Computing Based on Gate-Tunable 2D ...
Multi-Color Detection of Single Sensor Based on Tellurium Relaxation Char...
Uncooled InAsSb- based high- speed mid- wave infrared barrier detector
High Frequency Mid-Infrared Quantum Cascade Laser Integrated With Grounde...
Multi-function sensing applications based on high Q-factor multi-Fano res...
High-power electrically pumped terahertz topological laser based on a sur...
Van der Waals polarity-engineered 3D integration of 2D complementary logic
Distinguishing the Charge Trapping Centers in CaF2-Based 2D Material MOSFETs
Influence of Growth Process on Suppression of Surface Morphological Defec...
High-Power External Spatial Beam Combining of 7-Channel Quantum Cascade L...
官方微信
友情链接

High-sensitive microfluidic contact lens sensor for intraocular pressure visualized monitoring

2023-06-19
 Author(s): Yuan, M (Yuan, Miao); Liu, ZD (Liu, Zhiduo); Wu, XT (Wu, Xiaoting); Gou, HY (Gou, Haoyang); Zhang, YG (Zhang, Yugui); Ning, X (Ning, Xin); Li, WJ (Li, Weijun); Yao, ZH (Yao, Zhaohui); Wang, YJ (Wang, Yijun); Pei, WH (Pei, Weihua); Chen, HD (Chen, Hongda)
 
Source: SENSORS AND ACTUATORS A-PHYSICAL Volume: 354  Article Number: 114250  DOI: 10.1016/j.sna.2023.114250  Early Access Date: FEB 2023   Published: MAY 1 2023 
 
Abstract: Intraocular pressure (IOP) is the primary pathogenic indicator of glaucoma. Real-time IOP monitoring is significant for preventing, diagnosing, and treating glaucoma. Compared with contact lens sensors based on electronic components and photonic crystals, microfluidic contact lens sensors have the merits of good flexibility, straightforward IOP reading, and low cost. We report a high-sensitivity microfluidic contact lens sensor for direct IOP visual reading based on the bilateral wall structure. The bilateral wall structure substantially enhances the sensitivity and the linearity of the sensor. The dyed fish oil with good hydrophilicity, low viscosity, and almost non-volatile is selected as the liquid indicator. An automatic image processing program is designed to obtain the displacement of the liquid interface. The sensor exhibits a high sensitivity of 660 mu m/mmHg and a linear regression coefficient of 0.999 in the operating range of 10-30 mmHg. The sensor steadily responds to IOP changes after 24 h of the static test and maintains high synchronization with pressure in multiple cycles at a pressure change rate of 3 mmHg/s. With high sensitivity, linearity, and sufficient flexibility, the sensor holds excellent potential for clinic application of IOP monitoring.
 
Accession Number: WOS:000998093800001
 
ISSN: 0924-4247
 
eISSN: 1873-3069


关于我们
下载视频观看
联系方式
通信地址

北京市海淀区清华东路甲35号(林大北路中段) 北京912信箱 (100083)

电话

010-82304210/010-82305052(传真)

E-mail

semi@semi.ac.cn

交通地图
版权所有 中国科学院半导体研究所

备案号:京ICP备05085259-1号 京公网安备110402500052 中国科学院半导体所声明