A Model of Dual Fabry-Perot Etalon-Based External-Cavity Tunable Laser Us...
Internal motion within pulsating pure-quartic soliton molecules in a fibe...
Enhanced light emission of germanium light-emitting-diode on 150 mm germa...
The Fabrication of GaN Nanostructures Using Cost-Effective Methods for Ap...
Negative-to-Positive Tunnel Magnetoresistance in van der Waals Fe3GeTe2/C...
Quantum Light Source Based on Semiconductor Quantum Dots: A Review
A High-Reliability RF MEMS Metal-Contact Switch Based on Al-Sc Alloy
Development of a Mode-Locked Fiber Laser Utilizing a Niobium Diselenide S...
Development of Multiple Fano-Resonance-Based All-Dielectric Metastructure...
Traffic Vibration Signal Analysis of DAS Fiber Optic Cables with Differen...
官方微信
友情链接

Hermetic and Bioresorbable Packaging Materials for MEMS Implantable Pressure Sensors: A Review

2023-03-16

 

Author(s): You, ZW (You, Zhiwei); Wei, L (Wei, Lei); Zhang, ML (Zhang, Mingliang); Yang, FH (Yang, Fuhua); Wang, XD (Wang, Xiaodong)

Source: IEEE SENSORS JOURNAL Volume: 22 Issue: 24 Pages: 23633-23648 DOI: 10.1109/JSEN.2022.3214337 Published: DEC 15 2022

Abstract: Pressure sensors based on microelectromechanical system (MEMS) technology have been employed for measuring the pressure inside the human body due to their small size, lightweight, and low energy consumption. Hermetic packages are necessary to protect the implants from body fluid corrosion. Materials such as metal and glass are usually considered to be hermetic and can ensure several years of lifetime. Materials with low permeability, such as liquid crystal polymers and parylene, are also supposed to be short-term hermetic when the expected lifetime is not too long (less than a year). Water penetration and interface adhesion determine whether the package fails. Helium leakage tests and water concentration tests can be used to predict when the package fails. In addition, for more short-term implantable devices (several days or weeks), bioabsorbable packages can be helpful. The main advantage is that the self-degradation of the packaging material can avoid tissue damage caused by long-term implantation or infection caused by secondary removal surgery.

Accession Number: WOS:000928998600003

ISSN: 1530-437X

eISSN: 1558-1748

Full Text: https://ieeexplore.ieee.org/document/9925144/



关于我们
下载视频观看
联系方式
通信地址

北京市海淀区清华东路甲35号(林大北路中段) 北京912信箱 (100083)

电话

010-82304210/010-82305052(传真)

E-mail

semi@semi.ac.cn

交通地图
版权所有 中国科学院半导体研究所

备案号:京ICP备05085259-1号 京公网安备110402500052 中国科学院半导体所声明