A Model of Dual Fabry-Perot Etalon-Based External-Cavity Tunable Laser Us...
Internal motion within pulsating pure-quartic soliton molecules in a fibe...
Enhanced light emission of germanium light-emitting-diode on 150 mm germa...
The Fabrication of GaN Nanostructures Using Cost-Effective Methods for Ap...
Negative-to-Positive Tunnel Magnetoresistance in van der Waals Fe3GeTe2/C...
Quantum Light Source Based on Semiconductor Quantum Dots: A Review
A High-Reliability RF MEMS Metal-Contact Switch Based on Al-Sc Alloy
Development of a Mode-Locked Fiber Laser Utilizing a Niobium Diselenide S...
Development of Multiple Fano-Resonance-Based All-Dielectric Metastructure...
Traffic Vibration Signal Analysis of DAS Fiber Optic Cables with Differen...
官方微信
友情链接

Frequency Division Multiplexing and Normalized Harmonic Method for WMS Detection System in Multi-gas Detection

2023-02-08

 

Author(s): Yao, JQ (Yao, Jiaqi); Yuan, WY (Yuan, Wenyang); Gong, P (Gong, Ping); Xie, L (Xie, Liang)

Source: PHOTONICS Volume: 9 Issue: 11 Article Number: 850 DOI: 10.3390/photonics9110850 Published: NOV 2022

Abstract: A frequency division multiplexing (FDM) WMS system for multi-gas detection is reported in this paper. The distributed feedback lasers with different wavelengths adopt different modulation frequencies to achieve multi-components gas detection by the FDM technology. Combining optical path extension, normalized harmonic detection and wavelength modulation spectroscopy technology, the highly self-made system realized high sensitivity, high precision and short response time. The performance of this system was evaluated through the mixed gas of methane and hydrogen chloride. Experimental results show great linear response between gas concentration and normalized second harmonic (2f/1f) signal, the minimum detection limit (MDL) of the system is calculated to be 30.16 ppb for CH4 and 31.6 ppb for HCl with the integration time of 15 s. The MDL could be further enhanced to 11 ppb for CH4 and 13.1 ppb for HCl with an extended integration time. The maximum relative error is 2.16% and 3.19% for CH4 and HCl respectively.

Accession Number: WOS:000910891000001

Author Identifiers:

Author        Web of Science ResearcherID        ORCID Number

xie, liang                  0000-0003-4576-0225

eISSN: 2304-6732

Full Text: https://www.mdpi.com/2304-6732/9/11/850



关于我们
下载视频观看
联系方式
通信地址

北京市海淀区清华东路甲35号(林大北路中段) 北京912信箱 (100083)

电话

010-82304210/010-82305052(传真)

E-mail

semi@semi.ac.cn

交通地图
版权所有 中国科学院半导体研究所

备案号:京ICP备05085259-1号 京公网安备110402500052 中国科学院半导体所声明