A Model of Dual Fabry-Perot Etalon-Based External-Cavity Tunable Laser Us...
Internal motion within pulsating pure-quartic soliton molecules in a fibe...
Enhanced light emission of germanium light-emitting-diode on 150 mm germa...
The Fabrication of GaN Nanostructures Using Cost-Effective Methods for Ap...
Negative-to-Positive Tunnel Magnetoresistance in van der Waals Fe3GeTe2/C...
Quantum Light Source Based on Semiconductor Quantum Dots: A Review
A High-Reliability RF MEMS Metal-Contact Switch Based on Al-Sc Alloy
Development of a Mode-Locked Fiber Laser Utilizing a Niobium Diselenide S...
Development of Multiple Fano-Resonance-Based All-Dielectric Metastructure...
Traffic Vibration Signal Analysis of DAS Fiber Optic Cables with Differen...
官方微信
友情链接

A User-Friendly SSVEP-Based BCI Using Imperceptible Phase-Coded Flickers at 60Hz

2022-08-19

 

Author(s): Jiang, L (Jiang, Lu); Pe, WH (Pe, Weihua); Wang, YJ (Wang, Yijun)

Source: CHINA COMMUNICATIONS Volume: 19 Issue: 2 Pages: 1-14 Published: FEB 2022

Abstract: A brain-computer interface (BCI) system based on steady-state visual evoked potentials (SSVEP) was developed by four-class phase-coded stimuli. SSVEPs elicited by flickers at 60Hz, which is higher than the critical fusion frequency (CFF), were compared with those at 15Hz and 30Hz. SSVEP components in electroencephalogram (EEG) were detected using task related component analysis (TRCA) method. Offline analysis with 17 subjects indicated that the highest information transfer rate (ITR) was 29.80 +/- 4.65bpm with 0.5s data length for 60Hz and the classification accuracy was 70.07 +/- 4.15%. The online BCI system reached an averaged classification accuracy of 87.75 +/- 3.50% at 60Hz with 4s, resulting in an ITR of 16.73 +/- 1.63bpm. In particular, the maximum ITR for a subject was 80bpm with 0.5s at 60Hz. Although the BCI performance of 60Hz was lower than that of 15Hz and 30Hz, the results of the behavioral test indicated that, with no perception of flicker, the BCI system with 60Hz was more comfortable to use than 15Hz and 30Hz. Correlation analysis revealed that SSVEP with higher signal-to-noise ratio (SNR) corresponded to better classification performance and the improvement in comfortableness was accompanied by a decrease in performance. This study demonstrates the feasibility and potential of a user-friendly SSVEP-based BCI using imperceptible flickers.

Accession Number: WOS:000836008700001

ISSN: 1673-5447

Full Text: http://www.cic-chinacommunications.cn/EN/Y2022/V19/I2/1



关于我们
下载视频观看
联系方式
通信地址

北京市海淀区清华东路甲35号(林大北路中段) 北京912信箱 (100083)

电话

010-82304210/010-82305052(传真)

E-mail

semi@semi.ac.cn

交通地图
版权所有 中国科学院半导体研究所

备案号:京ICP备05085259-1号 京公网安备110402500052 中国科学院半导体所声明