A Model of Dual Fabry-Perot Etalon-Based External-Cavity Tunable Laser Us...
Internal motion within pulsating pure-quartic soliton molecules in a fibe...
Enhanced light emission of germanium light-emitting-diode on 150 mm germa...
The Fabrication of GaN Nanostructures Using Cost-Effective Methods for Ap...
Negative-to-Positive Tunnel Magnetoresistance in van der Waals Fe3GeTe2/C...
Quantum Light Source Based on Semiconductor Quantum Dots: A Review
A High-Reliability RF MEMS Metal-Contact Switch Based on Al-Sc Alloy
Development of a Mode-Locked Fiber Laser Utilizing a Niobium Diselenide S...
Development of Multiple Fano-Resonance-Based All-Dielectric Metastructure...
Traffic Vibration Signal Analysis of DAS Fiber Optic Cables with Differen...
官方微信
友情链接

Response to 14 MeV neutrons for single-crystal diamond detectors

2021-11-25

 

Author(s): Huang, GW (Huang Guang-Wei); Wu, K (Wu Kun); Chen, Y (Chen Ye); Li, LX (Li Lin-Xiang); Zhang, SY (Zhang Si-Yuan); Wang, ZG (Wang Zun-Gang); Zhu, HY (Zhu Hong-Ying); Zhou, CZ (Zhou Chun-Zhi); Zhang, YY (Zhang Yi-Yun); Liu, ZQ (Liu Zhi-Qiang); Yi, XY (Yi Xiao-Yan); Li, JM (Li Jin-Min)

Source: ACTA PHYSICA SINICA Volume: 70 Issue: 20 Article Number: 202901 DOI: 10.7498/aps.70.20210891 Published: OCT 20 2021

Abstract: Single-crystal diamond (SCD) detectors promise to have applications in neutron spectrometers and fusion neutron monitoring under high flux deuterium plasma. The response to 14 MeV neutrons for the SCD detector is studied in this paper. A high-performance SCD neutron detector is developed by processing cleaning wafer, depositing metal electrodes, annealing and wire-bonding. A fast-neutrons monitoring system containing the detector, preamplifier and digital multichannel analyzer is constructed, and the response to 14 MeV neutrons for the detector is measured on the K-400 neutron generator supported by China Academy of Engineering Physics. In addition, computational simulations of the energy deposition and detection efficiency of 14 MeV neutron through diamond are performed via Geant4 toolkit based on evaluated nuclear data libraries of ENDF-VIII.0, JEFF-3.3, BROND-3.1, JENDL-4.0u and CENDL-3.1. The methods of widening the simulation spectrum and calibration of measuring spectrum are presented in order that simulation results are in reasonable agreement with measured values. The results indicate that the energy deposition of 14 MeV neutrons incident on the C-12 can be more accurately calculated with CENDL-3.1 than with other data libraries. The elastic scattering and reaction of C-12(n, 3 alpha) are described more accurately with the CENDL-3.1, and the characteristic peaks of C-12(n, alpha)Be-9 matched well the calibrated testing spectrum and the after-widening simulation spectrum, with a difference between the simulated detection efficiency and measuring results being as low as 0.61%. The outcome measures are described as the standardized mean difference, with a detection efficiency of (3.31 x 10(-4) +/- 0.11 x 10(-4)) counts/n, an energy resolution of 4.02% +/- 0.09%, and a peaking channel of 1797.24 +/- 0.80, which suggest that the detector keeps stable well under a high neutron flux of 2 x 10(10) n/s for as long as 2 h. The results demonstrate that the SCD detector can be a promising candidate for monitoring 14 MeV D-T neutrons.

Accession Number: WOS:000710189000006

ISSN: 1000-3290

Full Text: http://wulixb.iphy.ac.cn/article/doi/10.7498/aps.70.20210891



关于我们
下载视频观看
联系方式
通信地址

北京市海淀区清华东路甲35号(林大北路中段) 北京912信箱 (100083)

电话

010-82304210/010-82305052(传真)

E-mail

semi@semi.ac.cn

交通地图
版权所有 中国科学院半导体研究所

备案号:京ICP备05085259-1号 京公网安备110402500052 中国科学院半导体所声明