A Model of Dual Fabry-Perot Etalon-Based External-Cavity Tunable Laser Us...
Internal motion within pulsating pure-quartic soliton molecules in a fibe...
Enhanced light emission of germanium light-emitting-diode on 150 mm germa...
The Fabrication of GaN Nanostructures Using Cost-Effective Methods for Ap...
Negative-to-Positive Tunnel Magnetoresistance in van der Waals Fe3GeTe2/C...
Quantum Light Source Based on Semiconductor Quantum Dots: A Review
A High-Reliability RF MEMS Metal-Contact Switch Based on Al-Sc Alloy
Development of a Mode-Locked Fiber Laser Utilizing a Niobium Diselenide S...
Development of Multiple Fano-Resonance-Based All-Dielectric Metastructure...
Traffic Vibration Signal Analysis of DAS Fiber Optic Cables with Differen...
官方微信
友情链接

Enhanced Sensitivity and Precision of Portable Mass Spectrometry (MS) with a Discontinuous Atmospheric Pressure Interface by Multiple Ion Injection

2021-05-20

 

Author(s): Li, J (Li, Jun); Wu, HM (Wu, Huanming); Yu, JC (Yu, Jiancheng); Zhang, JL (Zhang, Junliang); Wang, CL (Wang, Chenlu); Xu, FX (Xu, Fuxing); Wang, WM (Wang, Weimin); Xie, ZB (Xie, Zhibin); Yin, T (Yin, Tao); Tang, KQ (Tang, Keqi)

Source: ANALYTICAL LETTERS DOI: 10.1080/00032719.2021.1922430 Early Access Date: APR 2021

Abstract: The detection limit is one of the most important performance characteristics for portable mass spectrometers (MS). To significantly reduce the size and the weight, small vacuum pumps are used in portable MS which leads to the use of a discontinuous atmospheric pressure interface (DAPI). Multiple ion injections (M-DAPI), which accumulates ions through opening the DAPI pinch valve several times during the ion injection period while maintaining a radio frequency (RF) voltage continuously on the trap, was shown to improve the sensitivity of DAPI-based portable MS. A systematic investigation of the optimization of M-DAPI was performed. The primary parameters affecting the performance of M-DAPI were optimized and sensitivity and stability improvements are reported. An 11.6-fold improvement in sensitivity was achieved by M-DAPI compared to the single ion injection DAPI operation for 1 mu g/mL enrofloxacin. A more than 10-fold reduction in the limit of detection (LOD) to 0.01 mu g/mL was also obtained. In addition, the stability was improved by M-DAPI with a relative standard deviation of 14.4% compared to 4.6% for DAPI.

Accession Number: WOS:000648769700001

ISSN: 0003-2719

eISSN: 1532-236X

Full Text: https://www.tandfonline.com/doi/full/10.1080/00032719.2021.1922430



关于我们
下载视频观看
联系方式
通信地址

北京市海淀区清华东路甲35号(林大北路中段) 北京912信箱 (100083)

电话

010-82304210/010-82305052(传真)

E-mail

semi@semi.ac.cn

交通地图
版权所有 中国科学院半导体研究所

备案号:京ICP备05085259-1号 京公网安备110402500052 中国科学院半导体所声明