A Model of Dual Fabry-Perot Etalon-Based External-Cavity Tunable Laser Us...
Internal motion within pulsating pure-quartic soliton molecules in a fibe...
Enhanced light emission of germanium light-emitting-diode on 150 mm germa...
The Fabrication of GaN Nanostructures Using Cost-Effective Methods for Ap...
Negative-to-Positive Tunnel Magnetoresistance in van der Waals Fe3GeTe2/C...
Quantum Light Source Based on Semiconductor Quantum Dots: A Review
A High-Reliability RF MEMS Metal-Contact Switch Based on Al-Sc Alloy
Development of a Mode-Locked Fiber Laser Utilizing a Niobium Diselenide S...
Development of Multiple Fano-Resonance-Based All-Dielectric Metastructure...
Traffic Vibration Signal Analysis of DAS Fiber Optic Cables with Differen...
官方微信
友情链接

An Ultrasensitive Contact Lens Sensor Based On Self-Assembly Graphene For Continuous Intraocular Pressure Monitoring

2021-05-20

 

Author(s): Liu, ZD (Liu, Zhiduo); Wang, G (Wang, Gang); Ye, C (Ye, Chen); Sun, HY (Sun, Hongyan); Pei, WH (Pei, Weihua); Wei, CR (Wei, Chunrong); Dai, W (Dai, Wen); Dou, ZQ (Dou, Zhiqiang); Sun, QY (Sun, Qingyu); Lin, CT (Lin, Cheng-Te); Wang, YJ (Wang, Yijun); Chen, HD (Chen, Hongda); Shen, GZ (Shen, Guozhen)

Source: ADVANCED FUNCTIONAL MATERIALS Article Number: 2010991 DOI: 10.1002/adfm.202010991 Early Access Date: MAY 2021

Abstract: Elevated intraocular pressure (IOP) is the leading cause of glaucoma. As glaucoma is an irreversible neurological eye disease, it is urgent to realize timely and accurate IOP detection for diagnostic and therapeutic purposes. Here, a contact lens sensor for continuous IOP monitoring using self-assembly graphene (SAG), is developed. The combination of face-to-face water transfer printing and micro-electromechanical systems technology can realize the batch preparation of such a sensor. The sensor has good light transmittance and temperature stability. It exhibits an ultra-high IOP sensitivity of 1.0164 mV mm Hg-1 on a silicone eye, and 3.166 mV mm Hg-1 in vitro on the porcine eye with remarkable linearity. The sensitivity of the proposed sensor is high enough to be read by a commercial radio frequency identification read-write system for continuous wireless monitoring of IOP. Furthermore, the as-prepared sensor can work as normal for 24 h in phosphate buffer saline.

Accession Number: WOS:000649308000001

ISSN: 1616-301X

eISSN: 1616-3028

Full Text: https://onlinelibrary.wiley.com/doi/10.1002/adfm.202010991



关于我们
下载视频观看
联系方式
通信地址

北京市海淀区清华东路甲35号(林大北路中段) 北京912信箱 (100083)

电话

010-82304210/010-82305052(传真)

E-mail

semi@semi.ac.cn

交通地图
版权所有 中国科学院半导体研究所

备案号:京ICP备05085259-1号 京公网安备110402500052 中国科学院半导体所声明