A Model of Dual Fabry-Perot Etalon-Based External-Cavity Tunable Laser Us...
Internal motion within pulsating pure-quartic soliton molecules in a fibe...
Enhanced light emission of germanium light-emitting-diode on 150 mm germa...
The Fabrication of GaN Nanostructures Using Cost-Effective Methods for Ap...
Negative-to-Positive Tunnel Magnetoresistance in van der Waals Fe3GeTe2/C...
Quantum Light Source Based on Semiconductor Quantum Dots: A Review
A High-Reliability RF MEMS Metal-Contact Switch Based on Al-Sc Alloy
Development of a Mode-Locked Fiber Laser Utilizing a Niobium Diselenide S...
Development of Multiple Fano-Resonance-Based All-Dielectric Metastructure...
Traffic Vibration Signal Analysis of DAS Fiber Optic Cables with Differen...
官方微信
友情链接

Binning-based local-threshold filtering for enhancement of underwater 3D gated range-intensity correlation imaging

2021-04-25

 

Author(s): Yang, YQ (Yang, Yuqing); Wang, XW (Wang, Xinwei); Sun, L (Sun, Liang); Zhong, X (Zhong, Xin); Lei, PS (Lei, Pingshun); Chen, JN (Chen, Jianan); He, J (He, Jun); Zhou, Y (Zhou, Yan)

Source: OPTICS EXPRESS Volume: 29 Issue: 6 Pages: 9385-9395 DOI: 10.1364/OE.420359 Published: MAR 15 2021

Abstract: 3D gated range-intensity correlation imaging (GRICI) can reconstruct a 3D scene with high range resolution in real time. However, in the applications of underwater range-gated imaging, targets with low reflectivity or at a far distance typically have a low signal-to-noise ratio (SNR), especially in turbid water. Usually, a global threshold is set to suppress noise in gated images, which easily results in data holes in the degraded depth map reconstructed by 3D GRICI. To solve the problem, we have proposed a binning-based local-threshold filtering (BLF) algorithm to fill depth data holes. Firstly, raw gated images are added to obtain a sum image, and global threshold filtering and pixel binning for the sum image are used to obtain a reference image. Secondly, hole pixels can be registered according to the reference image. Finally, a smaller local threshold is reset for the hole pixels, and then a repaired depth map is given by 3D GRICI. The experimental results have shown that the proposed method can effectively fill depth data holes and the peak signal-to-noise ratio of the repaired depth map is increased from 10.23 dB to 22.45 dB by suppressing water noise with the improved range resolution from 6.25mm to 4.12 mm. In addition, the 3D depth of viewing is enlarged, and the limit detection distance is increased by 21% in experiment. The research can promote the practical applications of 3D GRICI. (C) 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement

Accession Number: WOS:000629298900116

PubMed ID: 33820367

ISSN: 1094-4087

Full Text: https://www.osapublishing.org/oe/fulltext.cfm?uri=oe-29-6-9385&id=449103



关于我们
下载视频观看
联系方式
通信地址

北京市海淀区清华东路甲35号(林大北路中段) 北京912信箱 (100083)

电话

010-82304210/010-82305052(传真)

E-mail

semi@semi.ac.cn

交通地图
版权所有 中国科学院半导体研究所

备案号:京ICP备05085259-1号 京公网安备110402500052 中国科学院半导体所声明