A Model of Dual Fabry-Perot Etalon-Based External-Cavity Tunable Laser Us...
Internal motion within pulsating pure-quartic soliton molecules in a fibe...
Enhanced light emission of germanium light-emitting-diode on 150 mm germa...
The Fabrication of GaN Nanostructures Using Cost-Effective Methods for Ap...
Negative-to-Positive Tunnel Magnetoresistance in van der Waals Fe3GeTe2/C...
Quantum Light Source Based on Semiconductor Quantum Dots: A Review
A High-Reliability RF MEMS Metal-Contact Switch Based on Al-Sc Alloy
Development of a Mode-Locked Fiber Laser Utilizing a Niobium Diselenide S...
Development of Multiple Fano-Resonance-Based All-Dielectric Metastructure...
Traffic Vibration Signal Analysis of DAS Fiber Optic Cables with Differen...
官方微信
友情链接

Wearable Contact Lens Sensor for Non-Invasive Continuous Monitoring of Intraocular Pressure

2021-03-25

 

Author(s): Dou, ZQ (Dou, Zhiqiang); Tang, J (Tang, Jun); Liu, ZD (Liu, Zhiduo); Sun, QG (Sun, Qigong); Wang, Y (Wang, Yang); Li, YM (Li, Yamin); Yuan, M (Yuan, Miao); Wu, HJ (Wu, Huijuan); Wang, YJ (Wang, Yijun); Pei, WH (Pei, Weihua); Chen, HD (Chen, Hongda)

Source: MICROMACHINES Volume: 12 Issue: 2 Article Number: 108 DOI: 10.3390/mi12020108 Published: FEB 2021

Abstract: Intraocular pressure (IOP) is an essential indicator of the diagnosis and treatment of glaucoma. IOP has an apparent physiological rhythm, and it often reaches its peak value at night. To avoid missing the peak value at night and sample the entire rhythm cycle, the continuous monitoring of IOP is urgently needed. A wearable contact lens IOP sensor based on a platinum (Pt) strain gauge is fabricated by the micro-electro-mechanical (MEMS) process. The structure and parameters of the strain gauge are optimized to improve the sensitivity and temperature stability. Tests on an eyeball model indicate that the IOP sensor has a high sensitivity of 289.5 mu V/mmHg and excellent dynamic cycling performance at different speeds of IOP variation. The temperature drift coefficient of the sensor is 33.4 mu V/degrees C. The non-invasive IOP sensor proposed in this report exhibits high sensitivity and satisfactory stability, promising a potential in continuous IOP monitoring.

Accession Number: WOS:000622842700001

PubMed ID: 33499080

eISSN: 2072-666X

Full Text: https://www.mdpi.com/2072-666X/12/2/108



关于我们
下载视频观看
联系方式
通信地址

北京市海淀区清华东路甲35号(林大北路中段) 北京912信箱 (100083)

电话

010-82304210/010-82305052(传真)

E-mail

semi@semi.ac.cn

交通地图
版权所有 中国科学院半导体研究所

备案号:京ICP备05085259-1号 京公网安备110402500052 中国科学院半导体所声明