A Model of Dual Fabry-Perot Etalon-Based External-Cavity Tunable Laser Us...
Internal motion within pulsating pure-quartic soliton molecules in a fibe...
Enhanced light emission of germanium light-emitting-diode on 150 mm germa...
The Fabrication of GaN Nanostructures Using Cost-Effective Methods for Ap...
Negative-to-Positive Tunnel Magnetoresistance in van der Waals Fe3GeTe2/C...
Quantum Light Source Based on Semiconductor Quantum Dots: A Review
A High-Reliability RF MEMS Metal-Contact Switch Based on Al-Sc Alloy
Development of a Mode-Locked Fiber Laser Utilizing a Niobium Diselenide S...
Development of Multiple Fano-Resonance-Based All-Dielectric Metastructure...
Traffic Vibration Signal Analysis of DAS Fiber Optic Cables with Differen...
官方微信
友情链接

Train-Induced Vibration Monitoring of Track Slab under Long-Term Temperature Load Using Fiber-Optic Accelerometers

2021-03-04

 

Author(s): Zhang, JX (Zhang, Jianxiang); Huang, WZ (Huang, Wenzhu); Zhang, WT (Zhang, Wentao); Li, F (Li, Fang); Du, YL (Du, Yanliang)

Source: SENSORS Volume: 21 Issue: 3 Article Number: 787 DOI: 10.3390/s21030787 Published: FEB 2021

Abstract: The train-induced vibration response provides a flexible solution for the real-time monitoring deformation of high-speed railway track slab in actual operation. This paper proposes a long-term real-time monitoring method for track slab deformation based on wavelet packet energy (WPE) using fiber optic accelerometers to record train-induced vibration. We found that the vibration response law of track slab deformation could be established by using the WPE of the frequency band covering the first- and second-order frequencies induced by the adjacent carriages. A field test was carried out for more than one year on the Beijing-Shanghai high-speed railway to investigate the train-induced vibration response law of track slab that was continuously deformed under a long-term temperature load. The maximum values of the WPE characteristic index appeared in winter and summer, and they were positively correlated with the temperature difference between the air environment and the track slab under the daily temperature load. These results were demonstrated to be consistent with the track slab deformation law for long-term and daily temperature loads. The novel method based on fiber optic accelerometers and WPE provides a new method for the long-term and real-time monitoring of track slab deformation.

Accession Number: WOS:000615512900001

PubMed ID: 33503941

eISSN: 1424-8220

Full Text: https://www.mdpi.com/1424-8220/21/3/787



关于我们
下载视频观看
联系方式
通信地址

北京市海淀区清华东路甲35号(林大北路中段) 北京912信箱 (100083)

电话

010-82304210/010-82305052(传真)

E-mail

semi@semi.ac.cn

交通地图
版权所有 中国科学院半导体研究所

备案号:京ICP备05085259-1号 京公网安备110402500052 中国科学院半导体所声明