A Model of Dual Fabry-Perot Etalon-Based External-Cavity Tunable Laser Us...
Internal motion within pulsating pure-quartic soliton molecules in a fibe...
Enhanced light emission of germanium light-emitting-diode on 150 mm germa...
The Fabrication of GaN Nanostructures Using Cost-Effective Methods for Ap...
Negative-to-Positive Tunnel Magnetoresistance in van der Waals Fe3GeTe2/C...
Quantum Light Source Based on Semiconductor Quantum Dots: A Review
A High-Reliability RF MEMS Metal-Contact Switch Based on Al-Sc Alloy
Development of a Mode-Locked Fiber Laser Utilizing a Niobium Diselenide S...
Development of Multiple Fano-Resonance-Based All-Dielectric Metastructure...
Traffic Vibration Signal Analysis of DAS Fiber Optic Cables with Differen...
官方微信
友情链接

Application of graphene nanowalls in an intraocular pressure sensor

2020-10-22

Author(s): Liu, ZD (Liu, Zhiduo); Wang, G (Wang, Gang); Pei, WH (Pei, Weihua); Wei, CR (Wei, Chunrong); Wu, XT (Wu, Xiaoting); Dou, ZQ (Dou, Zhiqiang); Li, YM (Li, Yamin); Wang, YJ (Wang, Yijun); Chen, HD (Chen, Hongda)

Source: JOURNAL OF MATERIALS CHEMISTRY B Volume: 8 Issue: 38 Pages: 8794-8802 DOI: 10.1039/d0tb01687j Published: OCT 14 2020

Abstract: As the second leading cause of blindness in the world, glaucoma is mainly caused by persistent high intraocular pressure (IOP) that compresses the optic nerve and causes permanent damage. Noninvasive continuous monitoring of IOP is an essential method for the diagnosis and treatment of glaucoma. In this paper, we propose a new strain gauge material based on graphene nanowalls (GNWs) for continuous monitoring of IOP with high sensitivity in a wide range. By simulation, we studied the relationship between the strain of the cornea and contact lens and IOP. The structure and the location of the GNWs in the contact lens are optimized. A method for transferring GNWs on contact lenses with the assistance of a gold film is proposed. The simulated tests on porcine eyes in vitro show that the resistance response of the device to normal IOP fluctuation reaches 1.014 k Omega mmHg(-1). Its normal sensitivity of 42 250 ppm mmHg(-1) and the response range of 0-75 mmHg are far more than those of most noninvasive methods reported before. This study shows the enormous potential of GNWs for continuous IOP monitoring with high sensitivity and low power consumption.

Accession Number: WOS:000576042800017

PubMed ID: 32869816

ISSN: 2050-750X

eISSN: 2050-7518

Full Text: https://pubs.rsc.org/en/content/articlelanding/2020/TB/D0TB01687J#!divAbstract



关于我们
下载视频观看
联系方式
通信地址

北京市海淀区清华东路甲35号(林大北路中段) 北京912信箱 (100083)

电话

010-82304210/010-82305052(传真)

E-mail

semi@semi.ac.cn

交通地图
版权所有 中国科学院半导体研究所

备案号:京ICP备05085259-1号 京公网安备110402500052 中国科学院半导体所声明