A Model of Dual Fabry-Perot Etalon-Based External-Cavity Tunable Laser Us...
Internal motion within pulsating pure-quartic soliton molecules in a fibe...
Enhanced light emission of germanium light-emitting-diode on 150 mm germa...
The Fabrication of GaN Nanostructures Using Cost-Effective Methods for Ap...
Negative-to-Positive Tunnel Magnetoresistance in van der Waals Fe3GeTe2/C...
Quantum Light Source Based on Semiconductor Quantum Dots: A Review
A High-Reliability RF MEMS Metal-Contact Switch Based on Al-Sc Alloy
Development of a Mode-Locked Fiber Laser Utilizing a Niobium Diselenide S...
Development of Multiple Fano-Resonance-Based All-Dielectric Metastructure...
Traffic Vibration Signal Analysis of DAS Fiber Optic Cables with Differen...
官方微信
友情链接

High-resolution and fast-response optical waveguide temperature sensor using asymmetric Mach-Zehnder interferometer structure

2019-11-28

 

Author(s): Niu, DH (Niu, Donghai); Zhang, DM (Zhang, Daming); Wang, LL (Wang, Lilei); Lian, TH (Lian, Tianhang); Jiang, MH (Jiang, Minghui); Sun, XQ (Sun, Xiaoqiang); Li, ZY (Li, Zhiyong); Wang, XB(Wang, Xibin)

Source: SENSORS AND ACTUATORS A-PHYSICAL Volume: 299 Article Number: UNSP 111615 DOI: 10.1016/j.sna.2019.111615 Published: NOV 1 2019

Abstract: We propose and demonstrate a high-resolution and fast-response optical waveguide temperature sensor based on asymmetric Mach-Zehnder interferometer (MZI) structure. The sensing region is composed of an asymmetric MZI structure, which consists of two different kinds of cores formed with commercial polymer materials EpoClad and Norland optical adhesive 73 (NOA 73), respectively, in the two arms. Due to the higher thermo-optic coefficient of NOA 73, the phase changes of the two MZI arms are different with the temperature which in turn induces output optical power variations, enabling simple and real-time temperature detection. The sensor exhibits a large sensitivity of -1.685 degrees C-1, high resolution of 1.48 x 10(-3) degrees C and fast response time of about 510 mus. The advantages of high sensitivity and resolution, low-cost, competent integration and compatible with most biological assays make the designed sensor potential application in temperature detections of molecular analysis, biotechnology and chemical synthesis. (C) 2019 Elsevier B.V. All rights reserved.

Accession Number: WOS:000496341800008

ISSN: 0924-4247

Full Text: https://www.sciencedirect.com/science/article/pii/S0924424719311379?via%3Dihub



关于我们
下载视频观看
联系方式
通信地址

北京市海淀区清华东路甲35号(林大北路中段) 北京912信箱 (100083)

电话

010-82304210/010-82305052(传真)

E-mail

semi@semi.ac.cn

交通地图
版权所有 中国科学院半导体研究所

备案号:京ICP备05085259-1号 京公网安备110402500052 中国科学院半导体所声明